Why Is The Top Section Of The Display Not Showing On The H5CN-[][][]M/H7CN-[][][]M Counter?

Modified on Sun, 11 May, 2025 at 10:23 PM

If a power interruption to the Counter occurs for 10 minutes or longer with the battery disconnected, errors will occur in the count value and display, even if the power recovers. Make sure a battery is connected to the Counter if the model has the suffix -M (backup function for power interruptions).

Any battery supplying 3 V can be used, but the data backup time depends on the capacity of the battery.
 

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article