What Happens If The L Terminal For Switching The Operation Mode Of EE-SX47/67 Or EE-SY67 Photomicro Sensors Is Connected To The Negative Terminal?

Modified on Sun, 11 May, 2025 at 10:19 PM

The operation mode will be the same as when the L terminal is open. Connecting the L terminal to the negative terminal will not result in failure or other problems, but the product is designed so that the L terminal is open or connected to the positive terminal, so leave it open or connect it to the positive terminal.
 