What Are The Restrictions When Soldering A165E Series Emergency Stop Switches?

Modified on Sun, 11 May, 2025 at 10:22 PM

There are the following restrictions.
  • Hand soldering: Use a 30-W soldering iron and complete soldering within 5 seconds.
  • Automatic soldering: Use dip soldering at 240°C and solder within 3 seconds.
  • Wait for one minute after soldering before exerting any external force on the solder.
 