What Is An Auxiliary Output?

Modified on Sun, 11 May, 2025 at 10:21 PM

F3SN/F3SH Series Safety Light Curtains

The default setting of the output is the reverse signal of the control output. It is only an auxiliary output, so do not use it as a control output for a safety circuit.
For F3SN-A and F3SH Series, the output operation mode can be selected using F39-MC11 Setting Console.
  • Dark-ON output = Control output and its reverse signal (default setting)
  • Light-ON output = Synchronized with the control output
  • Light diagnosis output
  • Lockout output
  • Outermost-beam monitoring output
  • Specified-beam output
  • Blanking monitoring output (F3SN-A only)
F3SL Series Safety Light Curtain

A signal is output in sync with the control output. It is only an auxiliary output, so do not use it as a control output for a safety circuit.
 